October 25, 2023
Request for inspection of ASTRO and CANYON GUIDE harnesses following the detection of a defect on the gated opening attachment point of an ASTRO harness. Due to the risk of unintentional opening of this attachment point, which could result in a life-threatening situation, we ask you to stop any use of these harnesses and to carry out immediately the following inspection.
Product name |
Picture | References | Serial numbers concerned |
---|---|---|---|
ASTRO BOD FAST european version | C083AA00 C083AA01 C083AA02 |
All serial numbers up to 23J 0000000 000 included | |
ASTRO BOD FAST international version |
C083BA03 |
All serial numbers up to 23J 0000000 000 included | |
ASTRO SIT FAST | C085AA00 C085AA01 C085AA02 |
All serial numbers up to 23J 0000000 000 included | |
CANYON GUIDE | C086BA00 C086BA01 |
All serial numbers up to 23J 0000000 000 included |
Components of the gated ventral attachment point:
The defect is due to a poor machining process of the metal D. This can cause the pin to slide completely sideways, despite the presence of the 2 screws. This situation presents a risk of death due to strangulation or falling from a height.
ASTRO BOD FAST & ASTRO SIT FAST |
CANYON GUIDE |
---|---|
1) Prepare for the test: In accordance with the instructions for use, check that the 2 screws are present and correctly installed. Remove any accessories mounted in the shackle connection holes. |
1) Prepare for the test: In accordance with the instructions for use, check that the 2 screws are present and correctly installed
|
2) Perform the test below: |
2) Perform the test below: |
The pin does not slide: The pin slides out completely: |
The pin does not slide: The pin slides out completely:
|
3) Test assessment: A) Compliant result
B) Non-compliant result
C) If you have any doubts about how to perform the testPlease contact your local support service team using this page.
Need a hard copy of this notice? Download PDF here
|
Where can I find the serial number of my harness?
The serial number is located on the plastic label inside the belt.
Does this apply to all colours of metal D?
Yes.
Do I have to dismantle my gated ventral attachment point to perform this inspection?
No.
I have a lanyard installed on my harness. Do I have to remove it?
No.
Do I need to check that the screws are tightened to the correct torque?
No, for this inspection, torque has no impact.
I've never used my harness, do I need to inspect it?
Yes.
I'm already using my harness, do I need to inspect it?
Yes.
Is it necessary to apply high pressure on the pin to detect this defect?
No, just a little pressure is necessary.
During the test, the pin does not slide but I notice a slight play, is this normal?
Yes, this is a normal functional play.
Have there been any injuries with the products affected by this information?
To date, no injuries have been reported.